Amajeneretha angochwepheshe afaka ulwazi oluningi lochwepheshe, futhi enye yazo ukuhlolwa kokufakwa kwamajeneretha. Namuhla, ngizokwethula ukuhlolwa kokufakwa kwamajeneretha kanye nezindaba ezidinga ukunakwa.

I-insulation ye-generator ihlukaniswe ngezinto ezimbili: ukufakwa kwe-stator kanye nokufakwa kwe-rotor.
I-Stator Insulation
Indawo yokulinganisa ye-stator insulation ikukhabhinethi ephansi yejeneretha engathathi hlangothi. I-stator insulation ingalinganiswa kuphela lapho i-rotor isesimweni esimile noma sokuvimbela, i-generator ikhokhiswa i-hydrogen kumfutho olinganiselwe, amanzi okupholisa e-stator afakwe ekusebenzeni, futhi ukuqhutshwa kwamanzi okupholisa kuzungeze i-0.2 μS / cm.
#1, indawo ephansi ye-generator neutral kufanele inqanyulwe, futhi i-PT trolley ye-generator kufanele ikhishwe. Bese, i-1000V insulation tester (megohmmeter) isetshenziselwa ukulinganisa. Kubhekwa njengokufanelekile lapho ukufakwa phakathi kwesigaba nomhlabathi kungengaphansi kuka-1MΩ.
#2, amaphuzu aphansi ama-voltage transformers ku-neutral ye-generator kanye ne-excitation transformer neutral kufanele inqanyulwe, futhi i-generator PT trolley kufanele ikhishwe. Bese, isihloli sokumelana nokufakwa kwe-2500V sisetshenziselwa ukulinganisa. Isikhathi sokufaka i-voltage yesilinganiso iminithi elingu-1. Uma izinga lokushisa lingaphansi kuka-20℃, ukufakwa phakathi kwesigaba nomhlabathi akufanele kube ngaphansi kuka-0.5MΩ, futhi isigaba ngasinye kufanele silinganiswe kanye esimweni sokufana sezigaba ezintathu. Uma inani elilinganisiwe lingaphansi kuka-80% yenani elingenhla noma umehluko kumanani wokufaka phakathi kwezigaba ungaphezu kuka-20%, ukugquma akufanelekile.
#3,#4,#5,iswishi yommese waphansi we-generator neutral kufanele ikhishwe, futhi inqola ye-PT generator kufanele ikhishwe. Bese, isihloli sokumelana nokufakwa kwe-1000V sisetshenziselwa ukulinganisa. Kubhekwa njengokufanelekile lapho ukufakwa phakathi kwesigaba nomhlabathi kungengaphansi kuka-0.8MΩ.
I-Rotor Insulation Measurement
Kuyunithi #1, sebenzisa isihloli sokumelana nokufakwa kwe-500V (megohmmeter). Ukumelana nokufakwa phansi kufanele kube kukhulu kuno-20MΩ.
Isilinganiso se-rotor insulation seYunithi #2 senziwa izisebenzi zokunakekela. Kudingeka ukuthi ukumelana nokufakwa phansi kube kukhulu kuno-100MΩ ku-20℃ futhi kukhulu kuno-50MΩ ku-30℃.
Okweyunithi #3, Iyunithi #4 kanye Neyunithi #5, sebenzisa isihloli sokumelana nokufakwa kwe-500V. Ukumelana nokufakwa phansi kufanele kube kukhulu kuno-1MΩ.
Izinyathelo Zokuqaphela Isilinganiso Sokufakwa Kwejeneretha
I-1) Ngesikhathi senqubo yokushintsha igesi kanye nokuhlolwa kokuvula nokuvala ama-switch unit e-generator-transformer, kuvinjelwe ngokuqinile ukulinganisa ukugxilwa kwazo zonke izingxenye ze-generator.
2) Ungasebenzisi i-insulation resistance tester ukukala ukumelana nokufakwa kwengxenye yokulawula kanye nemishini kagesi yekhabhinethi yokulungisa kabusha. Uma ukulinganisa kudingekile, kufanele kwenziwe ngabasebenzi abaqeqeshiwe.
3) Xhuma i-wiring ye-megohmmeter yamanzi ngendlela efanele ukuze uvimbele ukulimala ku-megohmmeter yamanzi.
4) Ipayipi lokuqoqa lamanzi okupholisa e-stator (amatheminali 94, 95, 96) kufanele asekelwe phansi ngokuthembekile ngemva kokulinganisa.
5) Lapho kulinganiswa ukuvaleka kwe-exciter rotor eyinhloko yeYunithi #1 kanye neYunithi #2, iswishi yokutholwa kokufakwa kwe-exciter rotor eyinhloko kufanele ishintshelwe endaweni yokuthi (ukulingisa Kweyunithi #2) (ukuhlolwa Kweyunithi #1).
6) Lapho ukala ukufakwa kwe-rotor ye-Generator #3 kanye ne-Generator #4, i-rotor grounding fuse kanye ne-rotor voltage isolation fuse kufanele idonswe ivuleke. Uma kungenjalo, i-fuse ingase iqhume.
7) Ngaphambi kokulinganisa ukufakwa kwe-low-voltage side winding ye-excitation transformer, amafuse e-DC capacitor, i-auxiliary transformer kanye ne-synchronous transformer kukhabhinethi yokulungisa kufanele idonswe ivuliwe.
I-8) Lapho ulinganisa ukufakwa kweyunithi ye-generator-transformer, ukushintshwa kwe-outlet yokunqamula i-transformer eyinhloko kanye nokushintshwa kwegatsha le-high-voltage service service transformer kufanele kube endaweni evulekile, futhi i-generator outlet PT kufanele ibe sesimweni esinqanyuliwe.
I-9) Kuvunyelwe kuphela ukukala ukufakwa kwe-generator lapho i-rotor ye-generator isesimweni esimile noma sokuvimbela ukuvimbela ukushaqeka kukagesi kubasebenzi noma ukulimala kwe-megohmmeter yamanzi.
Isitatimende: Ama-athikili akuwebhusayithi adalwa ekuqaleni inkampani ye-Jlmech (https://www.whjlmech.com) noma aphrintwe kabusha asuka kwenye imidiya yokuzenzela. Lapho ucaphuna noma uphrinta kabusha okuqukethwe kwalesi sihloko, sicela ubonise umthombo!
BUKA OKWENGEZIWE200kVA silent gen
BUKA OKWENGEZIWEIyunithi yejeneretha yezimboni
BUKA OKWENGEZIWE50KW 60Hz 220V generator diesel
BUKA OKWENGEZIWEamandla 30 kva
BUKA OKWENGEZIWE2 Iminyaka yewaranti isikhathi diesel generator
BUKA OKWENGEZIWE50kVA Silent Diesel Generator
BUKA OKWENGEZIWEcultivators mini tiller rotary
BUKA OKWENGEZIWEamajeneretha edizili yuchai 62 kva